LYSAGHT TOPSPAN® 40 steel roof batten is an economical alternative to timber battens. Made from high tensile steel, LYSAGHT TOPSPAN® 40 steel battens are lighter than timber battens, and nest together for easy transport and storage.
LYSAGHT TOPSPAN® 22 & 40 Steel Roof Battens
LYSAGHT TOPSPAN® 40 (Acad 2000) DXF file
LYSAGHT TOPSPAN® 40 (Acad 2000) DWG file
LYSAGHT TOPSPAN® 40 (Acad 2007) DXF file
LYSAGHT TOPSPAN® 40 (Acad 2007) DWG file
This search will find the ten closest suppliers for the location you enter, for the selected product. Fill in each of the fields below, then click "SEARCH"
Please note this locator only contains suppliers in AUSTRALIA. If you need suppliers in other countries please contact your local BlueScope Steel office.
Fields marked with * are required
Yes, it can. This means the support spacings can be increased. Please contact us for more information.
LYSAGHT TOPSPAN® 40 is suitable for use in cyconic regions when supplied in 0.75 BMT or greater.
Generally LYSAGHT TOPSPAN® 40 is sold in stock lengths of 7500mm. Custom cut lengths may be considered for large volume orders. Contact your local BlueScope Lysaght branch for further information.
For allowable Batten Spacing In Non-Cyclonic Areas, Download LYSAGHT TOPSPAN® 22 & 40 Steel Roof Battens (791 KB)
LYSAGHT TOPSPAN® 40 battens are made from TRUECORE® steel (aluminium/zinc alloy coated) complying with AS1397-2001 G550-AZ150 (550MPa minimum yield strength, 150g/m2 minimum coating mass)
| Product | Thickness (BMT mm) | Area (mm2) | Section Modulus (mm3) | Second Moment of Area (103mm4) | ||
|---|---|---|---|---|---|---|
| Zx | Zy | Ix | Iy | |||
| LYSAGHT TOPSPAN® 40 | 0.55 | 83 | 969 | 1080 | 20.6 | 39.7 |
| 0.75 | 113 | 1320 | 1475 | 28.1 | 54.1 | |
| Please note that the section modulus and secnd moment of area are both calculated about the principal axes | ||||||
LYSAGHT TOPSPAN® sections are availabile in all states.
LYSAGHT TOPSPAN® 22 & 40 Steel Roof Battens
LYSAGHT TOPSPAN® 40 (Acad 2000) DXF file
LYSAGHT TOPSPAN® 40 (Acad 2000) DWG file
LYSAGHT TOPSPAN® 40 (Acad 2007) DXF file
LYSAGHT TOPSPAN® 40 (Acad 2007) DWG file
Yes, it can. This means the support spacings can be increased. Please contact us for more information.
LYSAGHT TOPSPAN® 40 is suitable for use in cyconic regions when supplied in 0.75 BMT or greater.
Generally LYSAGHT TOPSPAN® 40 is sold in stock lengths of 7500mm. Custom cut lengths may be considered for large volume orders. Contact your local BlueScope Lysaght branch for further information.
For allowable Batten Spacing In Non-Cyclonic Areas, Download LYSAGHT TOPSPAN® 22 & 40 Steel Roof Battens (791 KB)
LYSAGHT TOPSPAN® 40 battens are made from TRUECORE® steel (aluminium/zinc alloy coated) complying with AS1397-2001 G550-AZ150 (550MPa minimum yield strength, 150g/m2 minimum coating mass)
| Product | Thickness (BMT mm) | Area (mm2) | Section Modulus (mm3) | Second Moment of Area (103mm4) | ||
|---|---|---|---|---|---|---|
| Zx | Zy | Ix | Iy | |||
| LYSAGHT TOPSPAN® 40 | 0.55 | 83 | 969 | 1080 | 20.6 | 39.7 |
| 0.75 | 113 | 1320 | 1475 | 28.1 | 54.1 | |
| Please note that the section modulus and secnd moment of area are both calculated about the principal axes | ||||||
LYSAGHT TOPSPAN® sections are availabile in all states.